MESSKO® BETECH®

Thermometer with bellow-type technology

MESSKO® BETECH® thermometers measure the oil and winding temperature (thermal image) in power transformers. The new Modbus-compatible generation is optimized for precise digital communication and integration into systems such as ETOS® and supports both analog and digital interfaces. MESSKO® BETECH® thermometers consist of a temperature sensor connected to the expansion bellows for the measurement display via a capillary tube, as well as an additional expansion bellows for compensation of the ambient temperature. This is based on robust bellows technology. MESSKO® BETECH® thermometers therefore impress with their reliability, durability, and efficiency at high switching capacities. 

Your Advantages at a Glance

  1. Robust expansion bellows technology

  2. Reliable even with high switching loads

  3. No readjustment or recalibration over the entire service life

  4. Contacts independently adjustable

  5. Compensation for ambient temperature

  6. Inspection glass made of composite safety glass with integrated UV filter

  7. Extremely durable and reliable

  8. Simple integration into ETOS® via RS485 Modbus RTU or 4...20mA

Show all

Product Information

Operating temperature -40...+70 °C (other measuring ranges available on request)
Ambient air temperature -40...+70 °C (other measuring ranges available on request)
Corrosion protection class C4H and CX (offshore)
Degree of protection IP 55 in accordance with EN60529 (optional: IP 65)
Cable gland Up to 3 x M20 and 1 x M16; ½” NPT; Pg16 adapter; M20 x 1.5 WADI (offshore), others on request
Interface/Output Digital: Modbus RTU RS 485 / Analog: 4...20 mA; 4...20 mA and 5 VDC; 0-5 V DC; Pt100;
Number of switches 2, 3, 4, 5 or 6
Measuring range Oil temperature: 0...+150°C or -20...+130°C or 0...+160°C or -40...+160°C; other ranges on request
Accuracy ± 3 °C (30-150 °C) / optional: ± 2°C or ± 1.5°C); according to IEC 60076-22-01:2019
Sensor gland Square flange 4–holes; G3/4"; G1"; 7/8"-14UNF; other thread joints on request
Measuring range 0 - 150° C or -20 - 130° C or 0 - 160° C or -40 - 160° C;
other ranges on request
Display accuracy ± 3° C (30 - 150 °C) (optional: ± 2 °C or ± 1.5 °C)
Installation Indoors and outdoors, tropic-proof
Ambient temperature -40 - 70 °C (optional: polar version down to -60 °C)
Insulation voltage 2.5 kV 50 Hz 1 min
Degree of protection IP 55 in accordance with EN60529 (optional: IP 65)
Outputs 4-20 mA; 4-20 mA and 5 V DC; 0-5 V DC; Pt100; Modbus RTU RS 485
Weight Approx. 4 kg
Micro-switches
Number 2, 3, 4, 5 or 6
Contact load Standard SPDT 250 V AC / 15 A; (optionally: MBO, DPDT or gold plated SPDT)
Switch hysteresis 12 ± 2 °C; others on request

Select language

Please make a selection to display suitable downloads
Operating temperature -40...+70 °C (other measuring ranges available on request)
Ambient air temperature -40...+70 °C (other measuring ranges available on request)
Corrosion protection class C4H and CX (offshore)
Degree of protection IP 55 in accordance with EN60529 (optional: IP 65)
Cable gland Up to 3 x M20 and 1 x M16; ½” NPT; Pg16 adapter; M20 x 1.5 WADI (offshore), others on request
Interface/Output Digital: Modbus RTU RS 485 / Analog: 4...20 mA; 4...20 mA and 5 VDC; 0-5 V DC; Pt100;
Number of switches 2, 3, 4, 5 or 6
Measuring range Oil temperature: 0...+150°C or -20...+130°C or 0...+160°C or -40...+160°C; other ranges on request
Accuracy ± 3 °C (30-150 °C) / optional: ± 2°C or ± 1.5°C); according to IEC 60076-22-01:2019
Sensor gland Square flange 4–holes; G3/4"; G1"; 7/8"-14UNF; other thread joints on request
Measuring range 0 - 150° C or -20 - 130° C or 0 - 160° C or -40 - 160° C;
other ranges on request
Display accuracy ± 3° C (30 - 150 °C) (optional: ± 2 °C or ± 1.5 °C)
Installation Indoors and outdoors, tropic-proof
Ambient temperature -40 - 70 °C (optional: polar version down to -60 °C)
Insulation voltage 2.5 kV 50 Hz 1 min
Degree of protection IP 55 in accordance with EN60529 (optional: IP 65)
Outputs 4-20 mA; 4-20 mA and 5 V DC; 0-5 V DC; Pt100; Modbus RTU RS 485
Weight Approx. 4 kg
Micro-switches
Number 2, 3, 4, 5 or 6
Contact load Standard SPDT 250 V AC / 15 A; (optionally: MBO, DPDT or gold plated SPDT)
Switch hysteresis 12 ± 2 °C; others on request

Select language

Please make a selection to display suitable downloads

Contact our Experts

United States of America


In order to offer you the best possible service, we would like to refer you directly to the right contact person. Please click on the following link.

US contacts

United States of America

QR

Scan the QR code to save the contact details as a VCF on your smartphone

Are you from another region or do you have questions about other topics?