MESSKO® Multi-Ballast

Multi ballast transformer

The universal ballast transforms the CT currents of 1 A, 1.5 A, 3 A, 4 A and 5 A to the current required for the thermal image. The ballast is suited for the TRASY2 and COMPACT series as well as for the BETECH series.

 

The different designs allow for flexible use:

- With housing (IP55, also for outdoor applications)
- Without housing, with mounting plate for control cabinet installation
- Without housing, with mounting plate and mounting clamp for cap rail in accordance with EN60715 The device with housing is supplied with M25 x 1.5 mm Hugro Wadi cable glands.

Your Advantages at a Glance

  1. Universal device for the TRASY2 and COMPACT series

  2. Transforms 1 A, 1.5 A, 3 A, 4 A and 5 A

  3. Different designs available for delivery

Show all

Product Information

Operating temperature -40 °C...+80 °C
Corrosion protection class C4H standard
Degree of protection IP55 in accordance with EN60529 (housed version) / IP00 in accordance with EN 61529 (control cabinet mounting)
Output 4...20 mA, Pt100
Cable gland 2 x M25 x 1.5 WADI, nickel-plated brass
Assembly plate Aluminum
Rail mounting clamp Aluminum, optional for rail mounting assembly acc. to EN60715, TH35-7,5 and TH35-15 respectively
Site of installation Control box location / indoor
Mounting position Any practical location
Degree of protection IP00 acc. to EN60529
Rated load Max. 30VA
Overload Max. 150% rated input current
Transformer precision ±2% at rated input current
Insulation voltage 2.5kV/1min. between terminals and housing
Ambient temperature -40 ..... +80°C
Operating temperature -40 °C...+80 °C
Corrosion protection class C4H standard
Degree of protection IP55 in accordance with EN60529 (housed version) / IP00 in accordance with EN 61529 (control cabinet mounting)
Output 4...20 mA, Pt100
Cable gland 2 x M25 x 1.5 WADI, nickel-plated brass
Assembly plate Aluminum
Rail mounting clamp Aluminum, optional for rail mounting assembly acc. to EN60715, TH35-7,5 and TH35-15 respectively
Site of installation Control box location / indoor
Mounting position Any practical location
Degree of protection IP00 acc. to EN60529
Rated load Max. 30VA
Overload Max. 150% rated input current
Transformer precision ±2% at rated input current
Insulation voltage 2.5kV/1min. between terminals and housing
Ambient temperature -40 ..... +80°C

Contact our Experts

United States of America


In order to offer you the best possible service, we would like to refer you directly to the right contact person. Please click on the following link.

US contacts

United States of America

QR

Scan the QR code to save the contact details as a VCF on your smartphone

Are you from another region or do you have questions about other topics?