#Pardot #LinkedIn

MESSKO® Pt-MU

Signal conditioner

Using the Pt-MU measuring transducer, the signal of a Pt100 is converted into a standard signal proportional to the temperature. For example, the measuring transducer can be connected to the Pt100 connections in the ZT-F2.1 transformer temperature sensor or the combi well. It prepares the output signals of these devices for further processes in the computer or electrical/electronic display. The Pt-MU is used anywhere where measured values need to be transmitted over large distances or interference fields are located in the transmission path.

Your Advantages at a Glance

  1. Measuring transducer for Pt100

Show all

Product Information

Input variable Resistance PT100
Rated values Any temperature range between -200 - 850 °C (minimum span 40 K)
Outputs 0-20 mA/0-500 Ohm load and 0-10 V max. 10 mA load as well as 4-20 mA/0-500 Ohm load and 2-10 V max. 10 mA load
Accuracy +/- 0,5% of full scale
Response time < 300 ms (with frequency module < 400 ms)
Operation temperature -15 to +20 to +30 to +55 °C
Storage temperature -25 - 85 °C
Temperature influence <0,2 % at 10 K
Ambient conditions Stationary application, weather protected, rel. air humidity 5 - 95 %, no condensation, altitude up to 2000 m, water, rain, snow or hail excluded
Input variable Resistance PT100
Rated values Any temperature range between -200 - 850 °C (minimum span 40 K)
Outputs 0-20 mA/0-500 Ohm load and 0-10 V max. 10 mA load as well as 4-20 mA/0-500 Ohm load and 2-10 V max. 10 mA load
Accuracy +/- 0,5% of full scale
Response time < 300 ms (with frequency module < 400 ms)
Operation temperature -15 to +20 to +30 to +55 °C
Storage temperature -25 - 85 °C
Temperature influence <0,2 % at 10 K
Ambient conditions Stationary application, weather protected, rel. air humidity 5 - 95 %, no condensation, altitude up to 2000 m, water, rain, snow or hail excluded

Contact our Experts

Andrew Gregory

Area Sales Manager Texas

Phone +1 731 618 6825
E-Mail A.Gregory@us.reinhausen.com
QR

Scan the QR code to save the contact details as a VCF on your smartphone

Edward Hed

Area Sales Manager Alaska, Hawaii, Idaho, Montana, Nebraska, Nevada, Oregon, Utah, Washington, Wyoming

Phone +1 731 618 2188
E-Mail E.Hed@us.reinhausen.com
QR

Scan the QR code to save the contact details as a VCF on your smartphone

Jose Febres

Area Sales Manager Arizona, California

Phone +1 731 487 9484
E-Mail J.Febres@us.reinhausen.com
QR

Scan the QR code to save the contact details as a VCF on your smartphone

Paul Shuttleworth

Area Sales Manager Colorado, Louisiana, New Mexico, Oklahoma

Phone +1 731 616 8729
E-Mail P.Shuttleworth@us.reinhausen.com
QR

Scan the QR code to save the contact details as a VCF on your smartphone

Pedro Munoz

Area Sales Manager Connecticut, Delaware, Maine, Maryland, Massachusetts, New Hampshire, New Jersey, New York, Pennsylvania, Rhode Island, Vermont

Phone +1 731 420 1779
E-Mail P.Munoz@us.reinhausen.com
QR

Scan the QR code to save the contact details as a VCF on your smartphone

Jarrad Weiss

Area Sales Manager Alabama, Florida, Georgia, South Carolina

Phone +1 731 618 9267
E-Mail J.Weiss@us.reinhausen.com
QR

Scan the QR code to save the contact details as a VCF on your smartphone

Patrick Wright

Area Sales Manager Illinois, Iowa, Kansas, Michigan, Minnesota, North Dakota, South Dakota, Wisconsin

Phone +1 513 940 2386
E-Mail P.Wright@us.reinhausen.com
QR

Scan the QR code to save the contact details as a VCF on your smartphone

Tony Boyd

Area Sales Manager Arkansas, Indiana, Kentucky, Mississippi, Missouri, Tennessee

Phone +1 731 394 5596
E-Mail T.Boyd@us.reinhausen.com
QR

Scan the QR code to save the contact details as a VCF on your smartphone

Karl Repko

Area Sales Manager North Carolina, Ohio, Virginia, West Virginia

Phone +1 731 217 0103
E-Mail K.Repko@us.reinhausen.com
QR

Scan the QR code to save the contact details as a VCF on your smartphone

To the Contact Finder

contact
Contact