ECOTAP® VPD® III

The compact class for distribution transformers

The ECOTAP® VPD® on-load tap-changer is the solution for all operators who have to maintain voltage in a defined and stable band in public, industrial and private distribution grids. We offer the right variant for every application.

Your advantages at a glance:

  1. Flexible

    One product family for all grid types and applications (transformers from all manufacturers; installation anywhere in the regulating winding)

  2. Sustainable

    Meets the requirements of the EU Ecodesign Directive. Operation also possible with natural esters as insulating liquid.

  3. Effective & uncomplicated

    Large regulating range with up to 17 operating positions. Commissioning and operation almost like an non-regulating distribution transformer.

  4. Durable & Resilient

    Autonomous voltage regulation (external control possible via communication). Service life similar to that of the distribution transformer. Maintenance-free thanks to proven MR vacuum technology.

Show all

Our product variants guarantee maximum flexibility

VPD III 30A – 24kV – 9 Positions VPD III 30A – 36kV – 9 Positions VPD III 100A – 40,5kV – 17 Positions VPD I 100A – 36kV – 9 Positions


The standard version with independent voltage regulation for distribution grids: compact, economical, maintenance-free


The variant with and for all options, even for large solar parks, battery storage or hydropower plants


The small on-load tap-changer with a large regulating range, for industrial applications with transformers up to approx. 8,000 kVA


The smallest on-load tap-changer in the world, especially for single-phase grid applications. Also for all pole-mounted transformers from 10kVA
Max. Primary voltage (highest voltage for operating equipment: 24kV 36kV 40,5kV 36kV
Max. Rated through-current 30A 30A 100A 100A
Number of phases: 3 3 3 1

A product that sets new standards

A product that sets new standards

Already installed in the oil-filled distribution transformer on delivery

Direct drive: : operates the on-load tap-changer and enables quick responses to changing grid situations.

On-load tap-changer: can be integrated into the transformer by any manufacturer.

Control unit: detects deviations via voltage measurement on the LV side and gives the switching impulse.

Communication: various optional communication protocols (and much more).

Individually configurable control unit:

CONTROL unit (standard)

Compact, robust, user-friendly and expandable. Automatic or manual operation, with complete parameterization possible on the control unit. Comprehensive status indicators on the display. Communication via MODBUS RTU

Control unit with DS option

With all CONTROL functions plus additional single-phase current measurement for dynamic adjustment of the voltage setpoint depending on the load flow as well as a measured value memory for current, voltage and derived values

 

CONTROL PRO extension

Optional additional functionality, e.g. with advanced voltage control algorithms, three-phase voltage and current measurement, parallel operation control or telecontrol communication in accordance with IEC 60870-4-104, IEC 61850, DNP3 or MODBUS TCP

Perfect integration into the transformer manufacturer's processes

Fast delivery times due to a small number of product variants; the standard variant ECOTAP® VPD III 30A - 24kV can also be supplied from stock. 

The compact dimensions of this on-load tap-changer allow it to be installed in almost all oil-filled distribution transformers, whether as a pole transformer or in a compact station. Compared to conventional transformers, only the height changes slightly. The proven electro-mechanical operating principle of MR vacuum technology guarantees decades of stable and reliable operation; the on-load tap-changer is maintenance-free over the service life of the transformer. The resistor-type on-load tap-changer principle with regulation on the high-voltage side avoids significant contributions to the losses of the transformer. This principle, which has been familiar to manufacturers and operators for decades, ensures that existing experience can be used for transformer design, production, testing and operation and that no extensive training is required.

ECOTAP® VPD® III

Do you have any questions?

Worldwide contacts

Uwe Firnhaber

Reinhausen GmbH

Phone +49 941 4090 6847
Mobile +49 151 1213 1395
E-Mail u.firnhaber@reinhausen.com
QR