In addition to petroleum-based insulating liquids in accordance with IEC 60296, which other insulating liquids are confirmed for use with Reinhausen tap-changers and accessories?

Modern insulating liquids place specific demands on tap-changers. Discover which insulating liquids have been tested and evaluated by Reinhausen.

Show the list of confirmed liquids    Download the brochure (PDF)

Why the insulating liquid and tap-changer must be considered together

Demand for less flammable and environmentally friendly alternatives to mineral oil is growing. However, tap-changers place particularly high demands on insulating liquids and were traditionally designed for use with mineral oil.

For synthetic esters, natural esters, bio-based hydrocarbons or GTL liquids, Reinhausen should always be consulted.

Tap-changer performance with modern insulating liquids

These properties differ from those of mineral oil and are addressed in the tap-changer design.

Electrical insulation

Rigorous voltage class sizing and suitable components ensure safe operation.

Thermal capacity

Esters behave thermally differently from mineral oil, so ratings are adjusted slightly.

Arc quenching capability

Higher ester viscosity is offset by minor adjustments to switching capacity or tie-in resistors.

Operating temperature

Esters need attention at low temperatures; GTL and bio-based hydrocarbons at high temperatures.

Material compatibility

Most materials are compatible; gaskets are replaced with elastomers such as FKM/Viton®.

Sealing systems

Natural esters require hermetically sealed systems to prevent oxidation and moisture ingress.

Recommended: OLTCs with vacuum technology (VACUTAP®, ECOTAP®). Reinhausen DETCs can also be used, ssubject to prior confirmation by Reinhausen.

Insulating liquids with general confirmation

Liquids with general confirmation for use with Reinhausen tap-changers and accessories. General confirmation does not replace a product- and application-specific assessment. Please inform Reinhausen which liquid you intend to use.

Synthetic EsterMidel 7131Shell
Synthetic EsterNycodiel 1255Nyco
Synthetic EsterNycodiel 1258Nyco
Synthetic EsterHyVolt SEErgon
Natural EsterFR3Cargill
Natural EsterMidel eN1215Shell
Natural EsterMidel eN1204Shell
Natural EsterBiotransol HFSavita
Natural EsterSK Supervolt Eco M/SHanyu
Natural EsterParyol Electra 7426Fratelli Parodi
Natural EsterBiotran-35Dongnam
Natural EsterBiotran-35SDongnam
Natural EsterPastell NeoLion
Bio-Based HydrocarbonNytro Bio 300XNynas
Gas-to-liquid (GTL)Diala S4 ZX-IShell
Gas-to-liquid (GTL)Diala S5 BDShell
Last updated: 21/10/2026

Do you have any questions?

Roberto Da Silva

Senior Engineer Insulating Liquids

Phone +55 11 99514-3716
E-Mail ro.dasilva@br.reinhausen.com
QR

Scan the QR code to save the contact details as a VCF on your smartphone

Question on a different topic ?

Related Products & Services

On-Load Tap-Changers

Beginning with OILTAP® technology, we were the world market leader in transformer tap-change operations. Our VACUTAP® technology revolutionized the on-load tap-changer yet again.

Oil Services | Analysis & Processing

The reliability of transformers is essential and optimised service is crucial, especially due to the ageing transformer fleets and the long delivery times for new equipment. The quality of the transformer oil plays a decisive role, as it fulfils several key functions.

OLTC Service | Maintenance and Inspection

To ensure reliable operation of your power transformer, the on-load tap-changer must function properly. To ensure this, professional maintenance is required for every on-load tap-changer, whether oil or vacuum technology.