Extend the service life of your transformers

by up to 50% with maintenance-free breathers and save on maintenance costs at the same time

Summary: Operators of electrical systems, energy suppliers and industrial companies are aware of the negative influence of humidity as an important catalyst for the aging process of transformers. Read this blog article to find out how you can extend the technical service life of transformers by up to 50%* and minimize maintenance costs and CO2 emissions by using maintenance-free dehydrating breathers.  

Find out more about the considerable savings potential within a few years despite higher initial investments. We also offer an expert consultation for free. 

Book expert call

About Maschinenfabrik Reinhausen:

More than 50% of the world's energy utilities rely on technology from Maschinenfabrik Reinhausen (MR) – including megacities such as New York and Shanghai as well as most of the global transformer industry. MR is the world market leader for the control of power transformers and pioneer of maintenance-free breathers. These offer the best price-performance ratio on the market and are intuitive to operate. MR has already supplied more than 8,000 customers in 185 countries and ensures simple installation and commissioning. 

From the challenge to the solution

Increasing operating times and rising current densities are placing ever greater demands on transformer components. Your existing transformer fleet should remain in operation for as long as possible, as replacement deliveries are expensive and can only be procured with a long lead time of up to five years in some cases.  

Optimum dehumidification is crucial for the trouble-free operation of transformers. The initial investment costs for breathers often only amount to a three-digit euro sum per unit. However, with negligent maintenance and the resulting increased ingress of moisture into the transformer, these components can cause very costly and irreparable damage that cannot always be detected immediately. Excessive moisture in the paper insulation considerably shortens the service life of transformers and leads to investment losses in the power supply.  

The reason for this is the irreversible aging process of the paper insulation. In addition to temperature, water plays a significant role in the aging of the solid and liquid insulation in the transformer. Moisture considerably weakens the insulation system, by significantly reducing the electrical and mechanical strength with increasing water content.  

Another challenge: conventional breathers may be inexpensive, but they require regular maintenance as the silica gel desiccant has to be replaced at regular intervals or depending on its condition. This entails a whole range of logistical challenges and costs: personnel and materials must be kept on hand for maintenance, and trips with on-site appointments must be planned. In addition, the desiccants used must be disposed of in an environmentally friendly manner. 

The service life of expensive, important transformers, which can only be reproduced with long lead times, can be extended by up to 50% by using maintenance-free dehydrating breathers. These automatically regenerate the used silica gel, thus relieving the operator of maintenance work.  

In maintenance-free dehydrating breathers with time-based regeneration, the bake-out process follows a fixed pattern. In maintenance-free breathers with an intelligent algorithm, humidity and temperature sensors analyze the operating cycles of your transformers to determine the optimum time for regeneration. If a saturation limit is exceeded, they automatically initiate the bake-out process. Data recordings provide in-depth insights into the operation of the transformer.  

The selection of the right dehydrating breather depends on various factors, including the size and importance of the transformer, operating conditions, emergency running properties, budget and other specific requirements such as load and operating cycles.  

Our free e-paper provides an in-depth insight into maintenance-free dehydrating breathers

+ Learn more about the application of maintenance-free dehydrating breathers
+ Comparison of conventional and maintenance-free dehydrating breathers
+ More than 18 pages full of background information

In use more than 100,000 times worldwide:

How maintenance-free breathers from MR can maximize the service life of transformers and significantly reduce operating costs

The maintenance-free breathers continuously dehumidify the insulating oil in power transformers. They regenerate themselves in the process. This ensures maximum operating times and safety and significantly reduces costs. More than 100,000 units have already   proven themselves worldwide even under extreme climatic conditions.

In regular operation, the air flowing to the oil expansion tank is passed over the silica gel desiccant and dried. The humidity level of the dried air flowing to the expansion tank is constantly monitored.

If it exceeds the defined threshold, the regeneration of the desiccant is activated – depending on the breathing cycle of the transformer. Sensor and status-controlled regeneration of the silica gel eliminates the costs associated with the frequent refilling of desiccant in conventional breathers, especially in areas with high humidity. 

 

How to retrofit transformers cost-effectively with maintenance-free dehydrating breathers

The maintenance-free breathers from MR can be easily attached to transformers and connected to any data platform with little effort.  

They are primarily aimed at operators of electrical systems, energy suppliers and industrial companies. As a rule, their service or asset managers are looking for reliable breathers to retrofit their existing transformer fleet.  

Would you like to be ready for the future with maintenance-free breathers?

Contact us for a free expert consultation

 

The advantages at a glance:

  • Actively protect the insulation medium from moisture 
  • Reduce operating costs and increases operational reliability 
  • State-dependent and self-learning algorithm 
  • Compliance with the IEC 60076-22-7 standard at all times  
  • Significantly higher efficiency than market competitors 
  • Easy to integrate into ETOS® (Embedded Transformer Operating System) 
  • Simple retrofitting to existing operating equipment 
  • Operating status display (LED) 
  • Test function (button for triggering the test for heating, sensors and displays) 
  • With app for easy data readout  

Maintenance-free dehydrating breathers pay for themselves after just a few years

Maintenance-free dehydrating breathers significantly reduce moisture absorption in the paper insulation and can therefore extend the service life of transformers by up to 50%*. Factors such as acquisition, maintenance and servicing costs and the effort involved are taken into account.   

The cost advantage compared to conventional breathers can be up to 65%. Despite higher initial costs for maintenance-free dehydrating breathers, the maintenance costs saved can lead to a return on investment (ROI) after less than three years.  

Investing in maintenance-free dehydrating breathers also helps to achieve ambitious sustainability goals. There is no need to dispose of used silica gel. Overall operating costs are reduced due to the elimination of regular maintenance. As a result, CO2 savings of up to 92% are possible. 

Request a free expert consultation now.

We work with you to evaluate the individual potential for your company. In a free 30-minute initial consultation, the focus is on needs analysis: we talk about your expectations and goals. We will provide you with "best practice" approaches for the use of our maintenance-free dehydrating breathers.

Contact us for a free expert consultation

References

* CIGRÉ Technical Brochure 349 "Moisture equilibrium and moisture migration within transformer insulation systems", 2008