VAM Analysis Service

The VAM takes the pulse of the on-load tap-changer – MR provides the diagnosis

The condition of the on-load tap-changer is critical for the operation of your transformers. Using vibro-acoustic measurements (VAM), you get meaningful data at an early stage. VAM records characteristic vibration signals that an on-load tap-changer emits during a tap-change operation. The installed MSENSE® VAM monitoring system, measurements taken on site by the MR TESSA® VAM service or your own devices, such as TESTRANO 600 from OMICRON, provide the data.


Request online now on myReinhausen
myReinhausen

Sus ventajas de un vistazo

  1. Flexibility

    Measurements regardless of transformer status (in/out of operation)

  2. Independence

    Available for MR on-load tap-changers as well as many third-party manufacturers

  3. Operating safety

    Detection of wear and aging for a safe, reliable tap-changer

  4. Database

    Detailed comparison with reference curves of the on-load tap-changer type from the MR database

  5. Report

    Extensive report with detailed illustrations and clear handling recommendations

  6. Versatility

    Can be combined with other services on the transformer, such as DGA or electrical measurements

Mostrar todo

Más información

Functional Scope

Creating meaningful diagnoses from the measured vibration signals is challenging and requires a detailed understanding of the switching sequences of on-load tap-changers. As the leading global manufacturer of on-load tap-changers, MR and its experts have unique knowledge in order to interpret VAM data thoroughly. 
The VAM ANALYSIS SERVICE from MR provides this knowledge in the form of a detailed report with information on the condition of the on-load tap-changer, as well as handling recommendations. The reports can be requested quickly and easily using the MR customer portal.

Functional scope
FINGERPRINT
BASIC
PREMIUM
Storage and management of VAM data in the MR customer portal
x
x
x
Structured visualization of the curves
x
x
x
Condition assessment of the OLTC
x
x
Recommendations for action for the OLTC
x
x
Visualization and analysis of irregular VAM data
x
x
Detection of peaks
x
Comparison of measurements with reference curves
x
Presentation of status quo for:
TESSA® VAM,
OMICRON TESTRANO 600,
MSENSE® VAM
Regulary assessment of
VAM data for:
MSENSE® VAM
Detailed analysis of VAM data for:
TESSA® VAM,
OMICRON TESTRANO 600,
MSENSE® VAM (in case of yellow events)

All services at a glance

Contact our Experts

Bastian Auerbach

Area Sales Manager

Only responsible for customer inquiries from the DACH region

Teléfono +49 (0)941 4090 5206
Móvil +49 (0)160 9729 8089
Correo electrónico B.Auerbach@reinhausen.com
QR

Escanee el código QR para guardar los datos de contacto como tarjeta de visita electrónica (TVE) en su teléfono smartphone

Al buscador de contactos