MESSKO® OLS

Oil level switch

Do you see potential for improvement in your existing oil level switches? Then MESSKO® OLS is your solution. The advanced oil level switch with integrated float technology ensures accurate monitoring of oil levels in your transformers. Even if gas accumulates under the cover, the measurement accuracy remains unaffected.

MESSKO® OLS is particularly suitable for use in wind power applications, due to its high corrosion resistance. It has passed the tests, which were carried out in accordance with IEC 60076-22-1 standard. To protect the sensitive floating system from fluid waves inside the transformer and from damage during installation, it is covered with a plastic tube. There is a test point or a screw option for venting the system.

The device can be easily screwed into the transformer using a G 1½ inch thread. A highlight of the design is the terminal box, which can be rotated 360° by hand from the customer.

Sus ventajas de un vistazo

  1. No readjustment or recalibration during the entire service life

  2. With durable coating to withstand offshore environments

  3. Functionally reliable and highly accurate thanks to state-of-the-art measuring technology

  4. Compact design for easy installation and integration

  5. 360° rotatable

Mostrar todo

Información sobre el producto

Field installation Indoors and outdoors
Measurement medium Alternative liquids (natural and synthetic ester or silicone oils on request)
Protection class IP 66 according to IEC 60529
Operating temperature -40 ... +115 °C
Insulating fluid temperature -25 ... +105 °C (max. +115 °C in overload situations)
Number of limit switches 1 CO contact
Limit switch capacity 24 V…230 V AC/DC, 3 mA ... 1 A, 0.75 VA ... 250 VA
House painting RAL 7035 (others on request)
Corrosion protection class CX corrosion class according to ISO 12944-9

Seleccionar idioma

Field installation Indoors and outdoors
Measurement medium Alternative liquids (natural and synthetic ester or silicone oils on request)
Protection class IP 66 according to IEC 60529
Operating temperature -40 ... +115 °C
Insulating fluid temperature -25 ... +105 °C (max. +115 °C in overload situations)
Number of limit switches 1 CO contact
Limit switch capacity 24 V…230 V AC/DC, 3 mA ... 1 A, 0.75 VA ... 250 VA
House painting RAL 7035 (others on request)
Corrosion protection class CX corrosion class according to ISO 12944-9

Seleccionar idioma

United States of America


In order to offer you the best possible service, we would like to refer you directly to the right contact person. Please click on the following link.

US contacts

United States of America

QR

Escanee el código QR para guardar los datos de contacto como tarjeta de visita electrónica (TVE) en su teléfono smartphone

¿Eres de otra región o tienes preguntas sobre otros temas?