MESSKO® MTRAB® 2.5

Maintenance-free dehydrating breathers

Ever longer operating times and ever higher current densities lead to constantly increasing demands on operating equipment. The maintenance-free MTRAB® dehydrating breathers continuously dehumidify and monitor the breathing cycle of power transformers - in all climatic zones. They regenerate themselves. This ensures maximum operating times and safety, and also massively reduces costs. The MTRAB® devices have been proven over 90,000 times worldwide. The intelligent algorithm ensures that the IEC 60076-22-7 standard is complied with at all times.

 

 

 

Your Advantages at a Glance

  1. Reduces operating costs and increases operational reliability

  2. Actively protects the insulation medium against humidity

  3. Condition-dependent and self-learning algorithm

  4. Significantly higher efficiency than market competitors

  5. Easy to integrate into ETOS® – Embedded Transformer Operating System

  6. Simple to retrofit on existing equipment

  7. Successful around the world and fit for the future in accordance with IEC 60076-22-7

show all

Product Information

Productvideo
APPLICATION MTRAB® 2.5-type SILICA GEL
Tap changer DB100 1,1 kg
Arc suppression coil (Petersen coil) DB100 1,1 kg
Air-filled cable terminal boxes DB100 1,1 kg
Traction transformers DB100 1,1 kg
Network transformers ≤40 MVA DB100T 1,1 kg
Phase shifters ≤ 40 MVA DB100T 1,1 kg
Reactors ≤ 40 MVA DB100T 1,1 kg
Network and step-up transformers > 40 MVA ≤ 200 MVA DB200T 2,2 kg
Phase shifters > 40 MVA ≤ 200 MVA DB200T 2,2 kg
Reactors > 40 MVA ≤ 200 MVar DB200T 2,2 kg
Generator and network coupling transformers 200 MVA DB200D or 2 x DB200T 4,4 kg
Phase shifters > 200 MVA DB200D or 2 x DB200T 4,4 kg
Reactors > 200 MVar DB200D or 2 x DB200T 4,4 kg
HVDC transformers DB200D or 2 x DB200T 4,4 kg
Furnace transformers DB200G 2 x 2,2 kg
Cavern transformers DB200G 2 x 2,2 kg
GSU machine transformers DB200G 2 x 2,2 kg

 

The MTRAB® 2.5 DB100 with alpha-control is a condition-controlled system, recommended for use on tap changers, arc suppression coils, air-filled cable terminal boxes and traction transformers. The desiccant is regenerated depending on the condition. Silica gel fill level: 1,1 kg with α-control.

Good to know: The main function of dehydrating breathers is to dehumidify the ambient air. As a result of the thermal compression of the insulation medium, the ambient air flows from the environment to the expansion tank of the transformer and tap changer (referred to as inhalation). During inhalation, moisture must be prevented from penetrating into the equipment with the air flow, as this reduces the insulating effect due to the contamination of the insulating medium.

The MTRAB® 2.5 DB100T with beta-control is a self-learning system, recommended for use on transformers with cyclic loads (network transformers, phase shifters, reactors). In addition to monitoring the humidity, the device determines a time window in which the oil conservator exhales and the desiccant is regenerated. Silica gel fill level: 1,1 kg with β-control.

Good to know: The main function of dehydrating breathers is to dehumidify the ambient air. As a result of the thermal compression of the insulation medium, the ambient air flows from the environment to the expansion tank of the transformer and tap changer (referred to as inhalation). During inhalation, moisture must be prevented from penetrating into the equipment with the air flow, as this reduces the insulating effect due to the contamination of the insulating medium.

The MTRAB® 2.5 DB200T with beta-control is a self-learning system, recommended for use on transformers with cyclic loads (network transformers, step-up transformers, phase shifters, reactors). In addition to monitoring the humidity, the device determines a time window in which the oil conservator exhales and the desiccant is regenerated. Silica gel fill level: 2,2 kg with β-control.

Good to know: The main function of dehydrating breathers is to dehumidify the ambient air. As a result of the thermal compression of the insulation medium, the ambient air flows from the environment to the expansion tank of the transformer and tap changer (referred to as inhalation). During inhalation, moisture must be prevented from penetrating into the equipment with the air flow, as this reduces the insulating effect due to the contamination of the insulating medium.

The MTRAB® 2.5 DB200D with beta-control is a self-learning system, recommended for use on transformers with cyclic loads (generator transformers, network coupling transformers, phase shifters, reactors, HVDC transformers). In addition to monitoring the humidity, the device determines a time window in which the oil conservator exhales and the desiccant is regenerated. Silica gel fill level: 2 x 2,2 kg with β-control.

Good to know: The main function of dehydrating breathers is to dehumidify the ambient air. As a result of the thermal compression of the insulation medium, the ambient air flows from the environment to the expansion tank of the transformer and tap changer (referred to as inhalation). During inhalation, moisture must be prevented from penetrating into the equipment with the air flow, as this reduces the insulating effect due to the contamination of the insulating medium.

The MTRAB® 2.5 DB200G with gamma-control is ideal for special applications, such as cavern transformers, furnace transformers and GSU machine transformers with aperiodic breathing behaviors. If the humidity level in the air flowing towards the transformer exceeds the standardized value, the desiccant chambers are regenerated in sequence. Silica gel fill level: 2 x 2,2 kg with γ-control.

Good to know: The main function of dehydrating breathers is to dehumidify the ambient air. As a result of the thermal compression of the insulation medium, the ambient air flows from the environment to the expansion tank of the transformer and tap changer (referred to as inhalation). During inhalation, moisture must be prevented from penetrating into the equipment with the air flow, as this reduces the insulating effect due to the contamination of the insulating medium.

The MTRAB® 2.5 is equipped with a data logger of the latest generation as standard (optional software needed). The MTRAB® MSET software allows the device function and processes (dehumidification and regeneration) to be monitored and analyzed at all times. This means that it ensures additional safety through equipment monitoring. Long-term analysis: Benefit from the key operating parameter – residual humidity – being recorded over a time period of up to 10 years. 

MTRAB® MSET is available in these language versions: German, English, Chinese, French, Italian, Korean, Portuguese, Russian, Spanish.

THE DEHYDRATING BREATHER FOR TRANSFORMERS AND TAP-CHANGERS FROM THE MARKET LEADER THAT HAS PROVEN ITSELF 90,000 TIMES OVER

Effectively prevent moisture in the insulation medium
LOWERING OPERATING EXPENSES, EXTENDING SERVICE LIFE

90,000 times

tested and proven worldwide – even under the most extreme conditions.
MTRAB® 2.5 is a tried and tested system – fit for the future in accordance with IEC 60076-22-7.
Technology from the market leader: dehumidifies and continuously monitors the respiratory cycle of the power transformer. Considerable cost savings.

 

The Latest Technology for Optimum Operation and Reduced Operating Costs

The Latest Technology for Optimum Operation and Reduced Operating Costs

  • Data logger incl. software (software optional)
  • Extended overvoltage protection in accordance with EN 60664-1 Category III
  • IP66/IP67 degree of protection
  • Corrosion protection C4H or CX in accordance with IEC 12944
  • Test button for manually checking the function, moisture level at the device output and message chains (included as standard)
  • Direct integration into monitoring and SCADA systems
  • Prepared for integration into ETOS® (optional)

maximizing operating times and reliability. increasing efficiency.

maximizing operating times and reliability. increasing efficiency.

  • Ever-longer operating times and ever-greater current densities lead to continuously increasing demands on equipment.
  • Optimal dehydration is the essential prerequisite for the health of your equipment.
  • The proven solution: the maintenance-free MTRAB® 2.5

ADVANTAGES OVER CONVENTIONAL SOLUTIONS

MTRAB® 2.5 DEHYDRATING BREATHER CONVENTIONAL DEHYDRATING BREATHERS
+ A significant increase in operational reliability thanks to the maintenance-free system - High risk for transformers if maintenance is not or is improperly carried out
+ The lack of required maintenance means visual inspections can be reduced to a minimum. - Regular visual inspection required throughout the entire service life of the transformer to check the moisture level of the desiccant
+ Cost-intensive, regular replacement of the desiccant is no longer necessary. This significantly reduces costs. - Regular replacement of the desiccant required throughout the entire service life of the transformer
+ Sensor- and status-controlled regeneration of the silica gel - Enormous costs due to frequent refilling of desiccant, in particular in regions with high humidity
+ No environmental or disposal problems arising from consumed desiccant - Environmental impact, disposal problems, and considerable costs due to consumed desiccant
+ Greater efficiency during dehydration thanks to the large contact surface and the technical design - Ineffective dehydration

 

Contact our Experts

Steve Averitt
Area Sales Manager
Alabama, Arkansas, Louisiana, Mississippi

Phone +1 731 4206049
E-Mail s.averitt@us.reinhausen.com

Scan the QR code to save the contact details as a VCF on your smartphone

Edward Hed
Area Sales Manager
Alaska, Idaho, Montana, Nebraska, Oregon, Utah, Washington, Wyoming

Phone +1 731 6182188
E-Mail e.hed@us.reinhausen.com

Scan the QR code to save the contact details as a VCF on your smartphone

Jesus Sanchez
Area Sales Manager
Arizona, Hawaii, California, Nevada, New Mexico

Phone +1 731 618 0906
E-Mail J.Sanchez@us.reinhausen.com

Scan the QR code to save the contact details as a VCF on your smartphone

Paul Shuttleworth
Area Sales Manager
Colorado, Oklahoma, Texas

Phone +1 731 6168729
E-Mail p.shuttleworth@us.reinhausen.com

Scan the QR code to save the contact details as a VCF on your smartphone

Anthony Milone
Area Sales Manager
Connecticut, Delaware, Maine, Maryland, Massachusetts, New Hampshire, New Jersey, New York, Pennsylvania, Rhode Island,, Vermont

Phone  +1 610 8238826
E-Mail a.milone@us.reinhausen.com

Scan the QR code to save the contact details as a VCF on your smartphone

Jarrad Weiss
Area Sales Manager
Florida, Georgia, South Carolina

Phone +1 731 6189267
E-Mail j.weiss@us.reinhausen.com

Scan the QR code to save the contact details as a VCF on your smartphone

Charley Harwell
Area Sales Manager
Illinois, Iowa, Kansas, Michigan, Minnesota, North Dakota, South Dakota, Wisconsin

Phone +1 513 9402386
E-Mail c.harwell@us.reinhausen.com

Scan the QR code to save the contact details as a VCF on your smartphone

Tony Boyd
Area Sales Manager
Indiana, Kentucky, Missouri, Tennessee

Phone +1 731 3945596
E-Mail t.boyd@us.reinhausen.com

Scan the QR code to save the contact details as a VCF on your smartphone