GRIDCON® STATCOM

Reactive Power Compensation with maximum regulation dynamics

GRIDCON® STATCOM enables efficient implementation of voltage stabilization and load-flow optimizing measures.

Sus ventajas de un vistazo

  1. Modular system approach enables power scaling up to 50 Mvar

  2. Compact design for high installation versality

  3. Adoptable to each medium voltage level

  4. Maximum reliability through redundancy at different system levels

  5. Low power losses because of 3-Level IGBT topology

  6. Simple service for individual components thanks to modular system approach

Mostrar todo

Información sobre el producto

  • Reducing operating costs:
    GRIDCON® STATCOM dynamically improves the power factor at the grid connection point, thereby supporting compliance with contractually stipulated connection conditions.
  • Preventing production disruptions:
    GRIDCON® STATCOM improves grid stability through dynamic supply of the regulating power.
  • Reducing investment costs:
    The standardized, modular system architecture of the GRIDCON® STATCOM makes it possible to offer cost-efficient solutions tailored to both the customer's needs and the application in question with reduced engineering and manufacturing work.
  • Reducing operating costs:
    GRIDCON® STATCOM dynamically improves the power factor at the grid connection point, thereby supporting compliance with contractually stipulated connection conditions.
  • Preventing production disruptions:
    GRIDCON® STATCOM improves grid stability through dynamic supply of the regulating power.
  • Reducing investment costs:
    The standardized, modular system architecture of the GRIDCON® STATCOM makes it possible to offer cost-efficient solutions tailored to both the customer's needs and the application in question with reduced engineering and manufacturing work.

NEW: GRIDCON® STATCOM MMC (Modular Multilevel Converter) Technology by MR

  1. E-House based (40 ft ISO-Containers, CSC certified)
  2. Valve room with MMC-Racks
  3. Cooling room with water cooling station
  4. Control room
  5. Reactors
  6. Cooling module, one for up to 36 kV

Direct connection to the grid, no transformer
Power range up to 36 kV and ±100 MVar
For industries and municipal applications

  • Maintain stable voltage 
    even during disturbances
  • Reduce voltage flicker 
    with heavy motors, arc furnaces, or welding
  • Improve power factor 
    and reduce electricity bills
  • Enhance equipment lifespan 
    through clean, stabilized power consumption
  • Increase productivity 
    by preventing downtime
  • Ensure grid compliance 
    and avoid penalties