ECOTRAC® SMART BREATHER
Dehydrating breather. Maintenance free. Attractive price.
Ever longer operating times and ever higher current densities lead to constantly increasing demands on operating equipment.
The maintenance-free ECOTRAC® SMART BREATHER continuously dehydrate and monitor on-load tap-changers, arc suppression coils and transformers, thus ensuring increased operational reliability.
Once a maximum humidity level has been exceeded, they regenerate themselves, ensuring low humidity in the inflowing air and thus also in the system oil. This ensures maximum uptime and safety and thereby massively reduces costs.
Sus ventajas de un vistazo
Información sobre el producto
Version |
SL | SH | ML | MH |
Characteristics | 1.1 kg Silikagel | 1.1 kg Silikagel | 2.2 kg Silikagel | 2.2 kg Silikagel |
0… + 70 °C no ModBus |
- 50… + 70 °C with ModBus |
0… + 70 °C no ModBus |
- 50… + 70 °C with ModBus |
|
1-2 pieces | EUR 2,200 | EUR 2,700 | EUR 3,100 | EUR 3,400 |
3-10 pieces | EUR 2,000 | EUR 2,400 | EUR 3,000 | EUR 3,300 |
11+ pieces | EUR 1,900 | EUR 2,300 | EUR 2,900 | EUR 3,100 |
net prices per piece in Euro, ex works | ||||
Order now |
ECOTRAC® SMART BREATER is part of our BUY ONLINE ONLY line.
ECOTRAC® SMART BREATHER |
Version SL/SH |
Version ML/MH |
|
Tap Changer and transformers (≤ 40 MVA) | Tap changer | X |
|
Arc suppression coil (Petersen coil) | X |
||
Traction transformers | X |
||
Network transformers | X |
||
Phase shifters | X |
||
Reactors | X |
||
Transformers (> 40 - ≤ 200 MVA) | Network and step-up transformers | X |
|
Phase shifters | X |
||
Reactors | X |
||
Order now |
ECOTRAC® SMART BREATHER |
||
Condiciones de servicio | Lugar de uso | interiores y aire libre |
Grado de contaminación (caja de conexiones) | 4 | |
Humedad relativa del aire (funcionamiento y almacenamiento | dentro de la caja de conexiones: 5…95 % (sin condensación) | |
Temperatura del aire ambiente | SL/ML: 0…+70 °C (+32…+158 °F) SH/MH: -50…+70 °C (-58…+158 °F) Versión con calefacción del filtro para aplicaciones en zonas frías, es decir, donde la temperatura ambiente se halla continuamente por debajo de 0 °C durante un periodo de 20 días. |
|
Temperatura de almacenamiento | -50 °C...+70 °C (-58…+158 °F) | |
Temperatura de servicio | SL/ML: 0…+70 °C (+32…+158 °F) SH/MH: -40…+70 °C (-40…+158 °F) Versión con calefacción del filtro para aplicaciones en zonas frías, es decir, donde la temperatura ambiente se halla continuamente por debajo de 0 °C durante un periodo de 20 días. |
|
Grado de protección conforme a IEC 60529 | todo el aparato: IPx6 con limitación, solo se permite chorro de agua desde arriba o lateralmente solo caja de conexiones: IP66 e IP67 |
|
Altura de instalación | máx. 4000 m sobre el nivel del mar (máx. 13 000 pies) | |
Tipos de versión | Materiales | Todas las piezas situadas en el exterior resistentes a la intemperie y a los rayos UV |
Color | Brida y piezas metálicas: anodizadas (aluminio) Caja de conexiones: con revestimiento de polvo (C4H según DIN EN ISO 12944-9) RAL7035 (gris luminoso) |
|
Peso (sin brida) | Variante S: aprox. 8,6 kg (19,0 lb) Variante M: aprox. 12,6 kg (27,8 lb) |
|
Brida de acoplamiento | Brida universal apta para brida triangular (DIN 42562) y bridas redondas de 4 orificios con un diámetro del círculo del tornillo de 75 a 110 mm, incl. kit de montaje y juntas | |
Alimentación | Tensión consigna | 100...127 V AC/DC, 50/60 Hz, Pmax. 2500 W o |
Consumo de corriente (en el funcionamiento normal) | ≤ 100 mA | |
Consumo energético (durante la regeneración) | Variante S: ≤ 1.3 A (at 120 V), ≤ 0.7 A (at 230 V) Variante M: ≤ 2.4 A (at 120 V), ≤ 1.3 A (at 230 V) |
|
Contactos de señalización | Tipo de contacto | 1 x contacto de transferencia, relé de aviso Regeneración de gel de sílice; 1 x contacto de transferencia, relé de aviso Avería del aparato (Fail Safe) |
Capacidad de ruptura admisible | 240 V CA, 8 A (IEC 61810, 100 000 ciclos de conmutación) 240 V CA, 10 A, 2000 VA (UL 508, 30 000 ciclos de conmutación) 30 V DC, 8 A, 240 W 240 V DC, 300 mA |
|
Capacidad de ruptura máxima | Según IEC 60076-22-7, 1000 ciclos de conmutación: 230 V CA, 1840 VA/cos phi > 0,5 250 V CA, 2500 W/carga óhmica 24 V CC, 192 W/carga óhmica |
|
Salidas analógicas (activas) | 1x output 4...20 mA | Temperatura: -40...+80 °C (-40…176 °F) 7.5 K/mA (13.5 °F/mA) Error de medición: +/- 2.3 K/mA (4.1 °F/mA) |
1x output 4...20 mA | Humedad del aire: 0...100% 6.25 % R.H./mA Error de medición: +/- 1.9% R.H. |
|
Opciones | Calefacción del filtro | Variantes SH y MH: con filtro de acero inoxidable calefactado, recomendado para zonas frías con temperatura ambiente continuamente por debajo de 0 °C durante un periodo de 20 días, para garantizar el funcionamiento. Punto de conmutación < 5 °C (conexión) |
Interfaz RS485 | Para la conexión a un sistema SCADA | |
Order now |
Seleccionar idioma
Version |
SL | SH | ML | MH |
Characteristics | 1.1 kg Silikagel | 1.1 kg Silikagel | 2.2 kg Silikagel | 2.2 kg Silikagel |
0… + 70 °C no ModBus |
- 50… + 70 °C with ModBus |
0… + 70 °C no ModBus |
- 50… + 70 °C with ModBus |
|
1-2 pieces | EUR 2,200 | EUR 2,700 | EUR 3,100 | EUR 3,400 |
3-10 pieces | EUR 2,000 | EUR 2,400 | EUR 3,000 | EUR 3,300 |
11+ pieces | EUR 1,900 | EUR 2,300 | EUR 2,900 | EUR 3,100 |
net prices per piece in Euro, ex works | ||||
Order now |
ECOTRAC® SMART BREATER is part of our BUY ONLINE ONLY line.
ECOTRAC® SMART BREATHER |
Version SL/SH |
Version ML/MH |
|
Tap Changer and transformers (≤ 40 MVA) | Tap changer | X |
|
Arc suppression coil (Petersen coil) | X |
||
Traction transformers | X |
||
Network transformers | X |
||
Phase shifters | X |
||
Reactors | X |
||
Transformers (> 40 - ≤ 200 MVA) | Network and step-up transformers | X |
|
Phase shifters | X |
||
Reactors | X |
||
Order now |
ECOTRAC® SMART BREATHER |
||
Condiciones de servicio | Lugar de uso | interiores y aire libre |
Grado de contaminación (caja de conexiones) | 4 | |
Humedad relativa del aire (funcionamiento y almacenamiento | dentro de la caja de conexiones: 5…95 % (sin condensación) | |
Temperatura del aire ambiente | SL/ML: 0…+70 °C (+32…+158 °F) SH/MH: -50…+70 °C (-58…+158 °F) Versión con calefacción del filtro para aplicaciones en zonas frías, es decir, donde la temperatura ambiente se halla continuamente por debajo de 0 °C durante un periodo de 20 días. |
|
Temperatura de almacenamiento | -50 °C...+70 °C (-58…+158 °F) | |
Temperatura de servicio | SL/ML: 0…+70 °C (+32…+158 °F) SH/MH: -40…+70 °C (-40…+158 °F) Versión con calefacción del filtro para aplicaciones en zonas frías, es decir, donde la temperatura ambiente se halla continuamente por debajo de 0 °C durante un periodo de 20 días. |
|
Grado de protección conforme a IEC 60529 | todo el aparato: IPx6 con limitación, solo se permite chorro de agua desde arriba o lateralmente solo caja de conexiones: IP66 e IP67 |
|
Altura de instalación | máx. 4000 m sobre el nivel del mar (máx. 13 000 pies) | |
Tipos de versión | Materiales | Todas las piezas situadas en el exterior resistentes a la intemperie y a los rayos UV |
Color | Brida y piezas metálicas: anodizadas (aluminio) Caja de conexiones: con revestimiento de polvo (C4H según DIN EN ISO 12944-9) RAL7035 (gris luminoso) |
|
Peso (sin brida) | Variante S: aprox. 8,6 kg (19,0 lb) Variante M: aprox. 12,6 kg (27,8 lb) |
|
Brida de acoplamiento | Brida universal apta para brida triangular (DIN 42562) y bridas redondas de 4 orificios con un diámetro del círculo del tornillo de 75 a 110 mm, incl. kit de montaje y juntas | |
Alimentación | Tensión consigna | 100...127 V AC/DC, 50/60 Hz, Pmax. 2500 W o |
Consumo de corriente (en el funcionamiento normal) | ≤ 100 mA | |
Consumo energético (durante la regeneración) | Variante S: ≤ 1.3 A (at 120 V), ≤ 0.7 A (at 230 V) Variante M: ≤ 2.4 A (at 120 V), ≤ 1.3 A (at 230 V) |
|
Contactos de señalización | Tipo de contacto | 1 x contacto de transferencia, relé de aviso Regeneración de gel de sílice; 1 x contacto de transferencia, relé de aviso Avería del aparato (Fail Safe) |
Capacidad de ruptura admisible | 240 V CA, 8 A (IEC 61810, 100 000 ciclos de conmutación) 240 V CA, 10 A, 2000 VA (UL 508, 30 000 ciclos de conmutación) 30 V DC, 8 A, 240 W 240 V DC, 300 mA |
|
Capacidad de ruptura máxima | Según IEC 60076-22-7, 1000 ciclos de conmutación: 230 V CA, 1840 VA/cos phi > 0,5 250 V CA, 2500 W/carga óhmica 24 V CC, 192 W/carga óhmica |
|
Salidas analógicas (activas) | 1x output 4...20 mA | Temperatura: -40...+80 °C (-40…176 °F) 7.5 K/mA (13.5 °F/mA) Error de medición: +/- 2.3 K/mA (4.1 °F/mA) |
1x output 4...20 mA | Humedad del aire: 0...100% 6.25 % R.H./mA Error de medición: +/- 1.9% R.H. |
|
Opciones | Calefacción del filtro | Variantes SH y MH: con filtro de acero inoxidable calefactado, recomendado para zonas frías con temperatura ambiente continuamente por debajo de 0 °C durante un periodo de 20 días, para garantizar el funcionamiento. Punto de conmutación < 5 °C (conexión) |
Interfaz RS485 | Para la conexión a un sistema SCADA | |
Order now |
Seleccionar idioma
With whom can I talk about this product?
With whom can I talk about this product?
Our Presales Team is ready and happy to assist you!
In case you have any questions or if you need further information, you are welcome to contact us directly via email:
Schedule an appointment