#Pardot #LinkedIn

MESSKO® IgT-MU

Signal conditioner

The IgT-MU measuring transducer is used to transform and galvanically isolate direct current or direct voltage into an impressed direct current and direct voltage signal. The calibrated double outputs can be switched between 0–20 mA and 0–10 V or between 4–20 mA and 2–10 V. It is installed in the control cabinet using 35 mm cap rails.

Your Advantages at a Glance

  1. Direct current measuring transducer

Show all

Product Information

Input variable Direct voltage or direct current
Rated values from 0-5 mV to 0-600 V, Ri = 100 kOhm/V, max. 2 MOhm
Outputs 0-20 mA/0-500 Ohm load and 0-10 V max. 10 mA load as well as 4-20 mA/0-500 Ohm load and 2-10 V max. 10 mA load, switchable on front side
Accuracy +/- 0,5% of full scale
Response time < 300 ms (with frequency module < 400 ms)
Operation temperature -15 to +20 to +30 to +55 °C
Storage temperature -25 - 85 °C
Temperature influence < 0,1% at 10 K
Ambient conditions No stationary application, weather protected, rel. air humidity 5 - 95%, no condensation, altitude up to 2000 m, water, rain, snow or hail excluded
Input variable Direct voltage or direct current
Rated values from 0-5 mV to 0-600 V, Ri = 100 kOhm/V, max. 2 MOhm
Outputs 0-20 mA/0-500 Ohm load and 0-10 V max. 10 mA load as well as 4-20 mA/0-500 Ohm load and 2-10 V max. 10 mA load, switchable on front side
Accuracy +/- 0,5% of full scale
Response time < 300 ms (with frequency module < 400 ms)
Operation temperature -15 to +20 to +30 to +55 °C
Storage temperature -25 - 85 °C
Temperature influence < 0,1% at 10 K
Ambient conditions No stationary application, weather protected, rel. air humidity 5 - 95%, no condensation, altitude up to 2000 m, water, rain, snow or hail excluded

Contact our Experts

Rodrigo Mecabo

Area Sales Manager Alabama, Arkansas, Louisiana, Mississippi

Phone +1 731 4206934
E-Mail R.Mecabo@reinhausen.com
QR

Scan the QR code to save the contact details as a VCF on your smartphone

Edward Hed

Area Sales Manager Alaska, Hawaii, Idaho, Montana, Nebraska, Nevada, Oregon, Utah, Washington, Wyoming

Phone +1 731 6182188
E-Mail e.hed@us.reinhausen.com
QR

Scan the QR code to save the contact details as a VCF on your smartphone

Jose Febres

Area Sales Manager Arizona, California

Phone +1 731 4879484
E-Mail J.febres@us.reinhausen.com
QR

Scan the QR code to save the contact details as a VCF on your smartphone

Paul Shuttleworth

Area Sales Manager Colorado, New Mexico, Oklahoma, Texas

Phone +1 731 6168729
E-Mail p.shuttleworth@us.reinhausen.com
QR

Scan the QR code to save the contact details as a VCF on your smartphone

Mark Andrews

Area Sales Manager Connecticut, Delaware, Maine, Maryland, Massachusetts, New Hampshire, New Jersey, New York, Pennsylvania, Rhode Island, Vermont, Virginia

Phone +1 731 487 4034
E-Mail M.Andrews@us.reinhausen.com
QR

Scan the QR code to save the contact details as a VCF on your smartphone

Jarrad Weiss

Area Sales Manager Florida, Georgia, South Carolina

Phone +1 731 6189267
E-Mail j.weiss@us.reinhausen.com
QR

Scan the QR code to save the contact details as a VCF on your smartphone

Patrick Wright

Area Sales Manager Illinois, Iowa, Kansas, Michigan, Minnesota, North Dakota, South Dakota, Wisconsin

Phone +1 513 9402386
E-Mail p.wright@us.reinhausen.com
QR

Scan the QR code to save the contact details as a VCF on your smartphone

Tony Boyd

Area Sales Manager Indiana, Kentucky, Missouri, Tennessee

Phone +1 731 3945596
E-Mail t.boyd@us.reinhausen.com
QR

Scan the QR code to save the contact details as a VCF on your smartphone

Karl Repko

Area Sales Manager North Carolina, Ohio, West Virginia

Phone +1 731 2170 103
E-Mail k.repko@us.reinhausen.com
QR

Scan the QR code to save the contact details as a VCF on your smartphone

To the Contact Finder

contact
Contact